Brand: Tranchart
Transportation: Ocean,Land
Place of Origin: China
Port: Shanghai,Ningbo,Nantong
Payment Type: L/C,T/T
Incoterm: FOB,CFR
PRODUCT NAME: | Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z) | RATED VOLTAGE: | 12KV |
RATED CURRENT: | 630, 1250, 2000, 2500, 3150 | RATED FREQUENCY: | 50Hz |
ALTITUDE: | ≤4000m | MEDIUM MATERIAL: | SF6 Gas |
APPLICATION: | Indoor | TYPE: | Fixed Type And Box Type |
General:
XGN75-12 (Z) Indoor gas insulation metal-clad switchgear adopted permanent magnet mechanism vacuum Circuit Breaker as main switch and HV live conductor is full-enclosed in SF6 room. It is suitable as a new generation metal-clad switchgear automatic-distribution, compact and able to extend.General:
This switchgear conforms to IEC 62271-200 and all primary components employed therein are in accordance with the relevant standards.
It is designed to accommodate high performance vacuum circuit breaker (VCB) which has been designed and tested in accordance with IEC62271-100.
The switchgear panels are suitable for the assembly of single &double busbar systems for indoor installation.
Characteristic:
1. Reliable
Each compartment is monitored individually &has its own pressure relief device.
Use of Vacuum circuit breakers with high number ofmechanical & electrical operations
Robust interlocking system
2. Safety
The primary side components are hermetically enclosed, gas filled compartment and thus insensitiveto atmosphere, dirt &dust.
Current Transformer are mounted outside the gas compartment & mounted on earthed LV compartment
3. Space saving
Smaller foot prints. All operations on the switchgear front
4. Economically efficient
Reduced space & surface area requirement.
Long service life
Maintenance free Gas compartment
Technical data:
S/NItemUnitData1Rated voltagekV122Rated currentA630 1250 2000 2500 31503Rated frequencyHz504Rated power frequency withstand voltage (1 min)Phase to phase, phase to earthkV42Insulation distance487Rated lightning impulse withstand voltagePhase to phase, phase to earthkV75Insulation distance8510Power frequency withstand voltage of auxiliary
control circuit (1 min)V200011Rated short-cricuit breaking current (rms)kA25 31.5 4012Rated short-circuti making currentkA63 80 10013Rated short time withstand currentkA/s25/4 31.5/4 40/414Rated peak withstand currentkA63 80 10015Degree of protection Gas-filled compartment : IP67
LV compartment: IP4X16Every phase main return circuit resistanceuΩ<25017Rated SF6 gas pressure (20ºC)Mpa0.04518Min SF6 gas pressure (20ºC)Mpa0.0319Annual SF6 gas loss rate%≤0.520Rated voltage of auxiliary control circuitVDC 110/220
AC 22021Dimensions (WxDxH)mm500x1200x2300
Product Categories : Ring Main Unit RMU > Gas-insulated Ring Main Unit