PRODUCT NAME: Ring Main Unit Switchgear Air Insulated Switchgear RATED VOLTAGE: 12KV
APPLICATION: Indoor RATED FREQUENCY: 50Hz
DEGREE OF PROTECTION IP2X STANDARD: IEC 298

Product introduction , HXGN11-12

Cubicle Fixed Indoor AC Metal-clad Ring Main Unit Switchgear ( "RMU") is a latest version of high voltage equipment by absorbing and digesting advanced technology in domestic and abroad, specially suitable for municipal power supply net of improvement and reconstruction. After a model approval test and a long-term running test, this product is certified to meet IEC298 standard Alternative Current Metal-clad Switchgear. Protection level of the product comes up to IP2X. It features small volume, light-weight, easy operation, small operative force, safety, easy maintenance, stable and reliable quality, free of fire disaster or explosion disaster, close to wall installation, small area occupied, etc. And if required, a three-phases coupling function could be satisfied.

RMU with three phases, 10kV rated voltage, 50Hz rated frequency, is suitable for power transmission and distribution system in places such as factory or mining enterprise, residential zone, high building, school, park, etc. It could also be used in ring net or terminal power supply.

Service condition

a. Altitude≤1000m
b. Ambient air temperature: Maximum +40ºC Minimum -35ºC
c. Relative humidity: Diary average value shall be not more than 95%; monthly average value shall be not more than 90%
d. Ambient air should be with no corrosion, no apparent pollution with combustible gas and etc.
e. Earthquake prevent function: process ground horizontal acceleration 0.2g and vertical acceleration0.1g at the same time, adopt resonance, sine, whip wave test, safety factor should be more than 1.67

Technical parameter of Ring Main Unit Switchgear Air Insulated Switchgear, HXGN11-12

S/N Description Unit Data
1 Rated voltage kV 12
2 Rated frequency Hz 50
3 Rated current of main busbar A 630
4 Rated short-time withstand current of main circuit, earth circuit kA/s 25/2
5 Rated peak withstand current of main circuit, earth circuit kA/s 63
6 Rated short circuit making current of main circuit, earth circuit kA/s 63
7 LBS full capacity breaking times times 100
8 Fuse breaking current kA/s 31.5 40
9 Mechanical endurance times 10000
10 1 min power frequency withstand voltage
phase to earth kV 42
phase to phase/ between isolating clearance kV 48
11 Lightning impulse withstand voltage (peak)
phase to earth kV 75
phase to phase/ between isolating clearance kV 85
12 1 min power frequency withstand voltage of Secondary circuit kV 2

Product Categories : Ring Main Unit RMU > Gas-insulated Ring Main Unit

Email to this supplier
  • *Subject:
  • *To:
    Mr. simon.tang
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
HomeProductsRing Main Unit RMUGas-insulated Ring Main UnitIEC 298 12KV Medium Voltage Ring Main Unit Switchg
Send Inquiry
*
*

simon.tang

Mr. simon.tang

SEND INQUIRY

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send