GCK Low Voltage Withdrawable Switchgear
GCK 320KW LV Withdrawable Switchgear MV Lv Switchgear
400/690V, 50/60 HZ ,400~6300A
Modular design, easily assembly
enclosure: Max. IP40
CCC,ISO9001,GB7251,IEC439
Send us your SLD (Single Line Drawing) or requirements, we design the switchgear plan for you.
General
GCK should be an improved economical type of MNS. The vertical row has no plastic functional panels. The door is fixed on the frame. After the door is opened, the drawer can be pulled out. G--cabinet structure; C--drawable type; K--control center.
Working environment
1. The ambient air temperature should not be higher than +40℃, not lower than -5℃, the average temperature within 24h should not be higher than +35℃ if it exceeds, it needs to be derated and run according to the actual situation;
2. Indoor use: the altitude of the place of use shall not exceed 2000m;
3. The relative temperature of the surrounding air should not exceed 50% when the temperature is +40℃. A larger relative temperature is allowed at a lower temperature, such as 90% when the temperature is +20℃. It should be considered that condensation may occur accidentally due to temperature changes. The impact of exposure;
4. When the device is installed, the inclination from the vertical plane does not exceed 5°C, and the entire group of cabinets is relatively flat (in accordance with the GBJ232-82 standard);
5. The device should be installed in a place where there is no severe vibration and impact, and where the electrical components are not corroded;
6. If the user has special requirements, it can be resolved through consultation with the manufacturer.
Technical Parameters
Insulation voltage: AC 660-1000V
Working voltage: AC 380-660 V
Frequency: 50Hz
Max current for feeder-circuit: 3150A
Max current for drawer-circuit: 3150A
Max capacity for control motor: 320KW
Horizontal bus peak withstand current (0.1S): 63/105/176KA
Horizontal busbar short-time withstand current (1S): 30/50/80/100 KA
Vertical bus peak withstand current (0.1S): 63/105 KA
Vertical busbar short-time withstand current (1s): 30/50 KA
Rating power frequency withstand voltage: 2500V(1min)
Secondary power frequency withstand voltage: 2500V (1min)
Protection level: IP30/40
Product Categories : Switchgear > Draw-out Type Low Voltage Switchgear Systems GCK
Mr. simon.tang
Tel:
86-519-85131880
Fax:
86-519-85131880
E-mail:
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.